Revolutionizing Bleeding Control: The Impact of Endoscopic Powder in MIS
Effective control of haemostasis is critical to the success of any surgical procedure. Beyond minimizing intraoperative blood loss, it significantly reduces the risks associated with transfusions and postoperative complications. Yet, minimally invasive surgeries—like laparoscopic and endoscopic interventions—make bleeding control more complex because of restricted maneuverability and visibility.
With the rise of less invasive surgery, adaptable and efficient haemostatic agents are more vital than ever, especially where standard techniques fail.
The Haemostatic Challenge in MIS
Compared to open surgeries, MIS—such as laparoscopic and endoscopic procedures—offers numerous benefits like reduced recovery time and smaller scars. These positive factors, however, increase the complexity of haemostasis. Limited maneuverability, constrained visualization, and the absence of tactile feedback make it harder to manage diffuse or irregular bleeding.
Suturing, tying, or cauterising are not always feasible in minimally invasive procedures. This is where topical haemostatic products—particularly endoscopic powders—are essential for boosting visibility and rapid bleeding control.
Surgi-ORC® Powder: An Innovative Haemostatic Solution
One of the most promising powdered forms—a plant-based, absorbable haemostat with a proven safety and efficacy profile. ORC was first introduced in 1943 in sheet form and has since evolved to meet the demands of modern MIS through powder formulations.
Why Surgi-ORC®-Based Endoscopic Powder Stands Out
• Accelerated Clotting: ORC’s mechanism enhances platelet activity and clot formation
• Adaptable Coverage: Powdered ORC easily conforms to irregular or deep wound areas
• Plant-Based Safety: Free from animal or human components, it reduces risks of immune reactions and disease transmission
• Antibacterial Environment: The oxidation process lowers pH, creating an acidic microenvironment that offers bactericidal benefits
• Biocompatible and Absorbable: Completely resorbed by the body with no cytotoxic effects, even near nerves or vessels
With these properties, Surgi-ORC® endoscopic powder is perfect for mild-to-moderate bleeding, particularly from capillaries, veins, or small arteries in hard-to-reach areas.
Delivery Devices: Enhancing Precision in MIS
The choice of delivery device plays a major role in the powder’s performance during MIS. Bellows pump applicators are commonly used for precise powder placement in minimally invasive settings.
Operation of Endoscopic Powder Applicators
These applicators—resembling syringe-like devices—are equipped with short or long applicator tips designed to deliver the powder through laparoscopic ports or trocars. The bellows mechanism lets surgeons deposit powder accurately without blocking the field of view.
Maximizing Effectiveness: Usage Tips
• Orientation: The angle of device orientation (vertical vs. horizontal) has a significant impact on the amount and spread of the powder. Surprisingly, orientation often affects performance more than the speed or force of compression
• Powder Characteristics: Particle size, flow, and how the powder handles moisture will affect performance
• Surgeon Technique: Output depends on the speed and force used when compressing the bellows
Real-World Applications of Endoscopic Powder
In cases where visibility is poor or anatomy is complex, endoscopic powder becomes an essential tool. Its flexible form lets it cover both wide wounds and tight spaces with equal efficiency.
Common Uses Include:
• Liver resections performed laparoscopically
• Thoracic surgery procedures
• Gynaecologic laparoscopic procedures
• Endoscopic procedures like ESD
• Minimally invasive urology surgeries
Using endoscopic powder helps surgeons see better, stop bleeding quicker, and complete operations faster—often with less need for transfusions and better patient outcomes.
Clinical Data Supporting ORC Powder
Research on SURGICEL® Powder in 103 surgical patients found:
• 87.4% haemostasis at 5 minutes, Endoscopic Powder rising to 92.2% at 10 minutes
• Excellent results across open and minimally invasive surgeries
• No product-related complications—no rebleeding, thromboembolism, or adverse reactions
• Surgeons found it easy to use, highly effective, and praised the precise delivery with little extra intervention needed
These findings confirm that SURGICEL® Powder is safe, efficient, and versatile, particularly for managing mild-to-moderate bleeding where traditional methods may fall short.
Summary
As MIS continues to evolve, so does the demand for advanced haemostatic tools. ORC-based endoscopic powders offer surgeons rapid, flexible, and reliable bleeding control options.
Whether you're managing bleeding in a deep pelvic space, a raw liver surface, or a narrow endoscopic field, ORC endoscopic powder delivers the performance and flexibility modern surgery requires—safely and effectively.
References
1. Zhang Y, Song D, Huang H, Liang Z, Liu H, Huang Y, Zhong C, Ye G. Minimally invasive hemostatic materials: tackling a dilemma of fluidity and adhesion by photopolymerization in situ. Scientific Reports. 2017 Nov 10;7(1):15250.
2. De la Torre RA, Bachman SL, Wheeler AA, Bartow KN, Scott JS. Hemostasis and hemostatic agents in minimally invasive surgery. Surgery. 2007 Oct 1;142(4):S39-45.
3. Al-Attar N, de Jonge E, Kocharian R, Ilie B, Barnett E, Berrevoet F. Safety and hemostatic effectiveness of SURGICEL® powder in mild and moderate intraoperative bleeding. Clinical and Applied Thrombosis/Hemostasis. 2023 Jul;29:10760296231190376.
4. Xiao X, Wu Z. A narrative review of different hemostatic materials in emergency treatment of trauma. Emerg Med Int. 2022;2022: 6023261
5. Stark M, Wang AY, Corrigan B, Woldu HG, Azizighannad S, Cipolla G, Kocharian R, De Leon H. Comparative analyses of the hemostatic efficacy and surgical device performance of powdered oxidized regenerated cellulose and starch-based powder formulations. Research and Practice in Thrombosis and Haemostasis. 2025 Jan 1;9(1):102668.
6. Bustamante-Balén M, Plumé G. Role of hemostatic powders in the endoscopic management of gastrointestinal bleeding. World Journal of Gastrointestinal Pathophysiology. 2014 Aug 15;5(3):284.
Comments on “The Blog on Endoscopic Powder”